Grizzl-E on a 100-Amp Panel: Current Settings Explained
The Grizzl-E Classic ships at 40A but can be set to 32A, 24A or 16A, each paired with a smaller dedicated circuit. A lower setting is one way to fit an EV charger on a 100A panel, at the cost of charging speed.
⚠️ Safety first: Work inside a panel or on a 240V circuit should be done by a licensed electrician, with a permit where your area requires one. This page explains the planning, not how to do the wiring.
The 60A starting figure is only an example. Use your own electrician's calculation for a real answer.
Current settings and circuit sizes
The United Chargers Grizzl-E Classic ships set to 40A and can be adjusted lower with DIP switches inside the unit. The installation manual pairs each setting with a dedicated circuit:
| Charger setting | Power | Dedicated circuit |
|---|---|---|
| 40A (factory default) | 9.6 kW | 50A |
| 32A | 7.7 kW | 40A |
| 24A | 5.8 kW | 30A |
| 16A | 3.8 kW | 20A |
Each setting needs a dedicated 208 to 240V circuit protected by a double-pole breaker rated for it.
Why we are not listing switch positions
The manual shows different switch positions for earlier 3-switch units and later 4-switch units. A wrong position can leave the charger set higher than the circuit allows, so follow the printed manual for your exact unit and have an electrician make the change. Always switch the circuit off first.
What the NEC says about adjustable settings
NEC 625.42(B) permits EVSE with adjustable current settings where access to the adjusting means is restricted. Changes that affect the rating label must follow the manufacturer's instructions, and the adjusted rating must appear on the label in a durable form. Ask your electrician and inspector how they want the lowered setting documented.
Plug type and breaker size must match
NEC Table 210.21(B)(3) pairs receptacle ratings with circuit ratings, so a 50A receptacle generally does not go on a 20A or 30A circuit. If you set the charger to 24A or 16A, ask your electrician whether to hardwire it or fit a receptacle that matches the lower breaker.
A lower setting charges more slowly but can make a 100A panel workable. See 100A panel and EV charger for the wider picture.
Sources
- United Chargers: Grizzl-E Classic installation manual
- ExpertCE: 2023 NEC changes to EVSE load calculations and adjustable settings
Frequently Asked Questions
Q: Can the Grizzl-E be set below 40A?
A: Yes. The installation manual lists 40A, 32A, 24A and 16A settings, selected with DIP switches inside the unit, each paired with a 50A, 40A, 30A or 20A dedicated circuit.
Q: Which breaker goes with a 24A Grizzl-E setting?
A: The manual pairs the 24A setting with a 30A dedicated circuit.
Q: Do I need to relabel the charger after lowering the current?
A: NEC 625.42(B) requires the adjusted rating to appear on the label in a durable form. Your electrician should handle this.